HAART 200
HAART 200AORTIC ANNULOPLASTY DEVICE

Simplifying
Aortic Valve Repair
HAART internal annuloplasty device is designed to restore full 3D annular stability of the aortic annulus. With simplified sizing ensuring optimal leaflet coaptation and annular size restoration, HAART devices can simplify repairs, allowing surgeons to replace only what is necessary.
HAART devices offer a unified repair approach for the many forms of Aortic Insufficiency, both in Bicuspid and Tricuspid valves.
CC-MK-001439 A
Features
Internal Annuloplasty for Bicuspid Aortic Valve
- Reduce & prevent annular dilatation
- Remodel the valve into a circular, 180° configuration
- Establish effective coaptation geometry and simplify leaflet repairs
3D Stability
Symmetric repair of bicuspid aortic valves has been shown to be the most durable reconstruction.1 The HAART 200 devices are designed to create a symmetric repair with the commissures positioned at 180°. The bicuspid annuloplasty devices are sized to maximize the non-fused cusp to comprise half of the valve. The other half of the valve is constructed from the two fused cusps.

The HAART 200 Aortic Annuloplasty Devices help establish effective coaptation geometry and simplify the leaflet repair procedures by:
- reducing annular dilatation and drawingthe leaflets toward the midline
- remodeling the valve into a circular,180° configuration.2
The subcommisural posts of the HAART 200 devices flare outward to mirror normal anatomic geometry and support a wide valve opening with low gradients.


Standardized Annuloplasty Technique
One repair approach for the many forms of Aortic Insufficiency.

Objective
Leaflet-Based Sizing
Leaflet free-edge measurements determine the normal annular dimension for improved leaflet coaptation

Internal Sub-valvular
Placement
Save time and avoid the deep root dissection and coronary reimplantation when not indicated

Simplified leaflet
Reconstruction
Devices recruit the leaflets towards the midline and provide a stable base for reproducible leaflet reconstruction
Innovative Sizing
Determined from leaflet free-edge length for improve leaflet coaptation, HAART's sizing is objective and reproducible.
Device Placement
Post & Looping sutures to ensure stable device to annulus fixation
Clinical Evidence
Growing evidence across broad applications

Mid-term outcomes

HAART in MICS


References
Schneider U. et al.
Long-term Results of Differentiated Anatomic Reconstruction of Bicuspid Aortic Valves.
JAMA Cardiol. 2020
Mazzitelli D, at al.
A Regulated Trial of Bicuspid Aortic Valve Repair Supported by Geometric Ring Annuloplasty.
Ann Thorac Surg 2015
Baker J.N. et al.
Minimally invasive aortic valve repair using geometric ring annuloplasty
J Card Surg, 2022
Gerdisch M.W. et al.
Early results of geometric ring annuloplasty for bicuspid aortic valve repair during aortic aneurysm surgery
JTCVS Techniques, 2022