This screen reduces the screen power consumption when you are not active on our site.This site uses technical cookies necessary for its operation and analytical cookies, including third-party anonymised cookies, to carry out aggregate statistical analysis. By closing the banner you consent to the processing of your personal data through the categories of cookies mentioned.
For more information about the cookies in operation on the site you can consult our Cookie Policy.
Close
Cookie PolicyHAART 200

HAART internal annuloplasty device is designed to restore full 3D annular stability of the aortic annulus. With simplified sizing ensuring optimal leaflet coaptation and annular size restoration, HAART devices can simplify repairs, allowing surgeons to replace only what is necessary.
HAART devices offer a unified repair approach for the many forms of Aortic Insufficiency, both in Bicuspid and Tricuspid valves.
CC-MK-001439 A
The HAART 200 is the only device for internal annuloplasty and was designed to support symmetric repair of bicuspid aortic valve.
Symmetric repair of bicuspid aortic valves has been shown to be the most durable reconstruction.1 The HAART 200 devices are designed to create a symmetric repair with the commissures positioned at 180°. The bicuspid annuloplasty devices are sized to maximize the non-fused cusp to comprise half of the valve. The other half of the valve is constructed from the two fused cusps.

The HAART 200 Aortic Annuloplasty Devices help establish effective coaptation geometry and simplify the leaflet repair procedures by:
The subcommisural posts of the HAART 200 devices flare outward to mirror normal anatomic geometry and support a wide valve opening with low gradients.


One repair approach for the many forms of Aortic Insufficiency.

Leaflet free-edge measurements determine the normal annular dimension for improved leaflet coaptation

Save time and avoid the deep root dissection and coronary reimplantation when not indicated

Devices recruit the leaflets towards the midline and provide a stable base for reproducible leaflet reconstruction
Determined from leaflet free-edge length for improve leaflet coaptation, HAART's sizing is objective and reproducible.
Post & Looping sutures to ensure stable device to annulus fixation




Schneider U. et al.
Long-term Results of Differentiated Anatomic Reconstruction of Bicuspid Aortic Valves.
JAMA Cardiol. 2020
Mazzitelli D, at al.
A Regulated Trial of Bicuspid Aortic Valve Repair Supported by Geometric Ring Annuloplasty.
Ann Thorac Surg 2015
Baker J.N. et al.
Minimally invasive aortic valve repair using geometric ring annuloplasty
J Card Surg, 2022
Gerdisch M.W. et al.
Early results of geometric ring annuloplasty for bicuspid aortic valve repair during aortic aneurysm surgery
JTCVS Techniques, 2022